Basement finish electrical in Westminster, CO
A basement finish in Westminster is a Residential Interior permit, and the electrical layout is part of the plans the City reviews. The City's building guide is specific about smoke and carbon monoxide alarms.
On this page
The permit
The City lists a basement finish under Residential Interior, work inside the home that requires plans, and points applicants to its Basement Finish Guide. If the home has a fire sprinkler system, additional permits may be required. For interior remodels, the same page asks for floor plans with room labels, dimensions, the locations of smoke and carbon monoxide alarms, and a description of all work. (City Resources)
What the plans must show
The City's basement guide, written by the Colorado Chapter of the International Code Council under the 2021 International Residential Code, asks for a floor plan showing "electrical outlets, smoke alarms, carbon monoxide alarms, lighting, fans," along with plumbing and heating equipment. (City basement guide)
Smoke alarms
From the same guide (City basement guide):
- Smoke alarms are required in all basements.
- If the finished basement has a sleeping room, alarms go in that room and in the hallway or area just outside it.
- Alarms added to meet these rules must be hardwired with battery backup and interconnected with the existing alarms.
- Where hardwiring would mean removing interior wall or ceiling finishes, battery-operated alarms are acceptable, and listed wireless alarms are acceptable.
Carbon monoxide alarms
CO alarms are required on each floor with bedrooms. The guide recommends placing them no farther than 15 feet from any bedroom entrance and not within 15 feet of a fuel-burning appliance. (City basement guide)
Lighting and ventilation
Lighting and ventilation are required for any finished part of the basement, and a ventilation fan vented outdoors is required in bathrooms with windows that do not open. (City basement guide)
Clearances around the furnace and water heater
The guide calls for at least 30 inches of clear working space in front of furnaces and water heaters, and says each appliance must be removable without disturbing wiring or junction boxes. (City basement guide) Keep that in mind when planning where new circuits and boxes go.
Planning the electrical side
- Will the new space need its own circuits, or a subpanel?
- Where will the GFCI protection be for a wet bar, bathroom or unfinished storage? See GFCI and AFCI.
- Is there room in the panel for the added circuits?
Frequently asked questions
Do basement smoke alarms need to be hardwired in Westminster?
Alarms added for a basement finish must be hardwired with battery backup and interconnected with existing alarms, per the City's basement guide. Battery or listed wireless alarms are acceptable where hardwiring would require removing finishes.
Does a basement finish need a permit in Westminster?
Yes. It is a Residential Interior permit, and the plans must show outlets, lighting, fans and smoke and CO alarm locations.
Sources
Checked November 18, 2026.